In MRI, TR primarily controls which type of contrast weighting?
In spin-echo imaging, TE primarily influences:
The Ernst angle is the flip angle that:
Compared with spin-echo, gradient-echo (GRE) sequences are more sensitive to:
FLAIR is an inversion-recovery sequence designed to:
STIR is primarily used to:
Chemical shift artifact (Type 1) occurs along which axis?
Increasing receiver bandwidth generally:
Parallel imaging (e.g., SENSE/GRAPPA) reduces scan time by:
Slice thickness is primarily set by:
Increasing NEX/NSA from 1 to 4 changes SNR by approximately:
Diffusion-weighted imaging contrast increases with higher:
Restricted diffusion typically appears as:
Time-of-flight (TOF) MRA relies on:
Phase-contrast (PC) MRA encodes:
BOLD fMRI signal mainly reflects:
At 3T compared with 1.5T, susceptibility artifacts are:
A zipper artifact across the image most often indicates:
Wrap-around (aliasing) occurs when:
Gradient duty cycle and dB/dt are safety concerns primarily due to:
SAR (specific absorption rate) is most affected by:
The projectile effect risk zone in MRI is designated as:
“Conditional” cardiac devices in MRI require:
Gadolinium-based contrast is relatively contraindicated in:
Dielectric shading at 3T is reduced by:
Flow compensation (gradient moment nulling) is used to:
Chemical fat suppression (SPAIR/SPIR) fails near metal mainly due to:
Dixon (fat–water) techniques separate signals by:
In-phase vs out-of-phase imaging is most useful for detecting:
Susceptibility artifacts are greatest with which readout?
Balanced SSFP (bSSFP/TrueFISP) images show:
Increasing matrix size (same FOV) primarily:
Motion ghosting typically appears along the:
k-space center primarily determines:
A magnet “quench” refers to:
Flow voids on spin-echo vascular images are due to:
Which adjustment most reduces susceptibility artifact?
For acute stroke MRI, DWI/ADC shows:
In MR safety screening, which item is high risk?
To shorten scan time without changing TR, you can primarily:
Chemical shift artifact Type 2 (“India ink”) appears as:
At 1.5T, a common FLAIR TI to null CSF is approximately:
A typical STIR TI to null fat at 1.5T is about:
The main trade-off when increasing receive bandwidth is:
Parallel imaging penalty most directly reflected by:
Best fix for bSSFP banding artifacts:
Diffusion EPI geometric distortion is reduced by:
Failure of chemical fat suppression near metal is mainly due to:
In-phase/out-of-phase liver imaging helps detect:
On MR spectroscopy, major peaks are typically at:
Lactate at TE ~135 ms characteristically:
Black-blood vessel wall imaging uses:
TOF MRA relies on:
Phase-contrast MRA encodes flow by:
Most effective way to reduce SAR in a TSE sequence:
Patient with MR-conditional pacemaker is scanned only when:
Primary risk from rapidly switched gradients is:
Dielectric shading at 3T is mitigated by:
Slice crosstalk is minimized by:
Partial Fourier (half-Fourier) trade-off:
Balanced SSFP contrast is primarily:
Best way to shorten scan time without changing TR/TE in 2D:
For acute stroke, DWI shows:
T2 shine-through is confirmed by:
Late gadolinium enhancement (LGE) nulling in myocardium aims to:
Ischemic infarct LGE pattern is typically:
Myocarditis LGE pattern commonly:
Arterial spin labeling (ASL) measures:
Best parameter change to reduce susceptibility artifact on GRE:
Wrap-around (aliasing) prevention option:
Coils: surface coil vs. body coil—SNR behavior?
Primary function of shimming:
Gadolinium in severe renal failure risk:
MR room safety zones:
Balanced SSFP artifacts around metal are reduced by:
DTI primary metric of anisotropy:
Motion ghosting is seen along which axis?
Dixon fat–water imaging advantage over chemical fat sat:
Main cause of “zipper” artifact:
To shorten a 3D GRE acquisition without changing TR/TE, you can:
Spoiled GRE (SPGR/FLASH) differs from balanced SSFP mainly in that it:
After gadolinium, which fat-suppression method is most appropriate for lesion conspicuity?
The “magic angle” effect causes increased tendon signal when fibers are oriented about:
Very long echo train length (ETL) in TSE/FASE most commonly produces:
In carotid 3D TOF MRA, to suppress venous signal you should place the saturation band:
In phase-contrast MRA, a VENC set too low will primarily cause:
Susceptibility artifact is usually worst at:
Around metallic implants, which sequence class typically minimizes blooming and distortion?
Multi-shot or segmented EPI DWI (e.g., RESOLVE) mainly helps by:
For contrast-enhanced MRA, centric k-space ordering is preferred because it:
Opposed-phase echo time at 1.5T is approximately:
Zero-filling interpolation primarily:
Nyquist (N/2) ghosting in EPI most commonly arises from:
Which change most reduces EPI geometric distortion?
SAR tends to scale with which parameter relationship?
To prevent RF burns, you should primarily:
Compared with 1.5T, T1 relaxation times at 3T are generally:
Balanced SSFP band spacing is primarily related to:
Respiratory motion reduction for liver MRI is best achieved with:
ECG gating primarily aims to:
Flow-compensated (gradient moment–nulled) sequences mainly reduce artifacts from:
MR-conditional implants can be scanned when:
First-trimester non-contrast MRI is generally:
Claustrophobia management in MRI can include:
SEMAC/MAVRIC metal reduction techniques primarily:
On diffusion, T2 shine-through should be distinguished from true restriction by:
The principal benefit of Dixon fat suppression over spectral fat sat is:
If opposed-phase liver imaging shows marked signal drop in an adrenal mass, the most likely diagnosis is: